[. . . ] Você pode sentir-se orgulhoso de possuir um Relógio SEIKO Duo-Display Cal. Para obter os melhores resultados, leia atentamente as instruções contidas neste opúsculo antes de usar o seu Relógio SEIKO Duo-Display. Conserve este manual para consultas futuras.
ENGLISH English
CONTENTS
Page
DISPLAY AND MODE CHANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TIME/CALENDAR SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (See the previous section)
Hour hand Second hand Minute hand
CROWN
Pull out when the second hand is at the 12 o'clock position. w Push back in to normal position when the second digits count "00" in the digital time display.
8
ALARM
English
q The alarm can be set to ring on a 24-hour basis.
ALARM TIME SETTING
A
w
Press to show ALARM mode. Press repeatedly to select the digits (flashing) to be adjusted.
Hour Minutes
B
B
w
ALARM mode
w
A
C A
Hour Minutes
or
C
w
Press to set the flashing digits. Press to return to ALARM mode.
B
ALARM mode mark
9
q ALARM ENGAGEMENT/DISENGAGEMENT
English
C
Alarm mark
With each press in ALARM mode, the alarm is alternately engaged and disengaged.
C
* At the designated time the alarm rings for 20 seconds. To stop it manually, press any of the buttons.
q TURNING ON/OFF OF THE HOURLY TIME SIGNAL
B C
Hourly time signal mark
B
and
C
With each simultaneous press in CALENDAR or TIME mode, the hourly time signal is turned on and off alternately.
10
STOPWATCH
q The stopwatch measures up to 60 minutes in 1/100 second increments.
English
A
Press to show STOPWATCH mode.
B
A
C
Minutes
Seconds
1/100 seconds
Standard measurement
C
START
C
STOP
B
RESET 11
w
w
English
Accumulated elapsed time measurement
C
START
C
STOP
C
C
STOP
B
RESET
w
w
w
RESTART
* Restart and stop of the stopwatch can be repeated by pressing button C.
Split time measurement
C
START
B
SPLIT
B
C
STOP
w
B
RESET
w
w
w
SPLIT RELEASE
* Measurement and release of split time can be repeated by pressing button B.
Measurement of two competitors
C
START
B
FINISH TIME OF 1ST COMPETITOR
C
2ND COMPETITOR FINISHES
B
FINISH TIME OF 2ND COMPETITOR
w
B
RESET
w
w
w
12
w
ILLUMINATING LIGHT
English
C C
Press and hold in TIME or CALENDAR mode.
* The light illuminates the digital display for easy viewing in the dark.
13
English
14
NOTES ON USING THE WATCH
TIME/CALENDAR SETTING
[CALENDAR SETTING] q The calendar automatically adjusts for odd and even months except February of leap years. q If the watch is left untouched in the CALENDAR SETTING display with the digits flashing, it will automatically return to the CALENDAR mode in 1 to 2 minutes. [DIGITAL TIME SETTING] q The flashing digits except the seconds and the 12-/24-hour indication move quickly if button C is kept pressed. q In setting the seconds, when the seconds read any number from "30" to "59" and button C is pressed, one minute is added and the seconds are reset to "00". q Changeover between 12- and 24-hour indications is made alternately with each press of button C. q When setting the hour digits in the 12-hour indication, check that AM/PM is properly set. q If the watch is left untouched in the TIME SETTING display with the digits flashing, it will automatically return to the TIME mode in 1 to 2 minutes. [ANALOGUE TIME SETTING] q When setting the minute hand, first advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact minute. q When the crown is pulled out or pushed in for time setting, the minute hand may move slightly. However, this is not a malfunction.
ALARM
English
[ALARM TIME SETTING] q When the time function is displayed in the 24-hour indication, the alarm is also displayed in the 24-hour indication. q When setting the hour digits in the 12-hour indication, check that AM/PM is properly set. q If the watch is left untouched in the ALARM SETTING display with the digits flashing, it will automatically return to the ALARM mode in 1 to 2 minutes. q The alarm can be tested by keeping buttons B and C pressed at the same time in the CALENDAR or TIME mode.
STOPWATCH
q With each press of button C, the light illuminates the digital display with a beep. q After measuring 60 minutes, the stopwatch will start counting again from "00'00"oo" as many times as necessary until it is stopped. q When measuring a long period of time, press button A to return the STOPWATCH mode to the CALENDAR or TIME mode after the stopwatch starts. This will prevent any possible malfunction.
15
BATTERY CHANGE
English
3
Years
The miniature battery which powers your watch should last approximately 3 years. [. . . ] This condition, however, will be corrected when the watch returns to normal temperature.
* Pressure in bar is a test pressure and should not be considered as corresponding to actual diving depth since swimming movement tends to increase the pressure at a given depth. ** We recommend that you wear a SEIKO Diver's Watch for scuba diving.
English
s TEMPERATURES
Your watch works with stable accuracy within a temperature range of 5°C and 35°C (41°F -5°C and 95°F). Temperatures over 50°C (122°F) or below 5°C (+23°F) may cause a slight time loss or gain or battery leakage or shorten the battery life. Hour, minutes and seconds "PM" mark in the 12-hour indication (Alarm mark and hourly time signal mark) STOPWATCH mode . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]